HAL
Halcyon Aerospace Components
Build Log + Standards Capture
Manager view

Standards capture, live across the floor

Gaps captured during builds aggregated into a training backlog. One flow replaces the time card and the standards binder.

Open gaps
15
Gaps this week
18
Builds at risk
4
LMS modules pending
7
Severity
Distribution
High19
Medium14
Low5
Category mix
By type
38
gaps
  • Training gap10
  • Supplier issue9
  • Tolerance ambiguity6
  • Fixture undocumented6
  • SOP gap4
  • Other3
Builds
Top by gap count
HAL-ST-30919
Aft Bulkhead Fastener Set
HAL-LG-22186
Nose Gear Trunnion Pin
HAL-FS-11625
Cross-Feed Fuel Valve Body
HAL-ST-31045
Wing Spar Splice Plate
HAL-FS-11485
Fuel Manifold Block
Open gaps
Filterable backlog
WhenBuildWorkerSeverityCategoryDescriptionStatus
May 6, 10:43 AMHAL-ST-3091
Tomás Ferreira
HW-004
HighTolerance ambiguityPrint calls out 0.0005 TIR but does not specify the reference datum.In review
May 6, 09:54 AMHAL-FS-1162
Ana Reyes
HW-001
HighSupplier issue3.1 cert references a test method the supplier has not been requalified on.Open
May 6, 06:14 AMHAL-ST-3091
Marcus Doyle
HW-002
HighSupplier issueSupplier shipped a heat treat that is one revision behind the current spec.In review
May 5, 02:56 PMHAL-EN-4412
Carla Mendez
HW-009
MediumTolerance ambiguityProfile tolerance applied to a feature without a clear basic dimension chain.In review
May 4, 08:33 AMHAL-FS-1162
Marcus Doyle
HW-002
HighSupplier issueTwo recent lots from the same supplier showed grain orientation outside the spec.Open
May 4, 08:08 AMHAL-ST-3104
Tomás Ferreira
HW-004
HighTraining gapApprentice asked to set up a tombstone fixture without prior advanced fixturing training.In review
May 3, 11:53 PMHAL-FS-1162
Naomi Park
HW-011
MediumTolerance ambiguityTolerance band on the radius blends into stock allowance, no clear acceptance line.Open
May 3, 10:57 PMHAL-FS-1148
Hassan Al-Said
HW-008
HighSupplier issue3.1 cert references a test method the supplier has not been requalified on.Open
May 2, 11:13 AMHAL-ST-3091
Marcus Doyle
HW-002
LowOtherTime clock punched against a closed work order, root cause not yet logged.In review
May 2, 08:47 AMHAL-FS-1148
Tomás Ferreira
HW-004
HighFixture undocumentedProbing routine uses a custom datum sphere not listed in the fixture inventory.In review
May 2, 06:31 AMHAL-ST-3091
Linnea Holm
HW-005
HighFixture undocumentedBay 4 tombstone fixture has an undocumented spacer stack required for this part.In review
May 1, 05:36 PMHAL-ST-3091
Naomi Park
HW-011
MediumSupplier issueSupplier shipped a heat treat that is one revision behind the current spec.In review
May 1, 04:16 PMHAL-ST-3091
Marcus Doyle
HW-002
HighTraining gapApprentice asked to set up a tombstone fixture without prior advanced fixturing training.Training scheduled
Apr 30, 04:52 PMHAL-EN-4412
Naomi Park
HW-011
MediumTraining gapInspector unfamiliar with the AS9100 first-article documentation packet structure.Open
Apr 30, 10:15 AMHAL-LG-2218
Devon Walker
HW-006
HighSupplier issue3.1 cert references a test method the supplier has not been requalified on.In review
Apr 30, 02:38 AMHAL-LG-2207
Ana Reyes
HW-001
MediumOtherTool crib was missing the spec gauge required for the in-process check.Open
Apr 29, 08:10 AMHAL-ST-3091
Tomás Ferreira
HW-004
HighTraining gapApprentice asked to set up a tombstone fixture without prior advanced fixturing training.Open
Apr 29, 04:23 AMHAL-LG-2218
Tomás Ferreira
HW-004
MediumFixture undocumentedVacuum chuck pattern was modified last month, change not captured in the fixture book.Open
Apr 29, 02:15 AMHAL-FS-1162
Yuki Tanaka
HW-007
HighTraining gapApprentice asked to set up a tombstone fixture without prior advanced fixturing training.Open
Apr 28, 11:59 AMHAL-LG-2207
Ana Reyes
HW-001
MediumFixture undocumentedWedge fixture for thin-wall finish op has no torque spec posted at the cell.Open
Apr 28, 04:36 AMHAL-ST-3104
Devon Walker
HW-006
LowSOP gapOperator could not locate a current SOP for this specific subassembly variant.Training scheduled
Apr 28, 02:35 AMHAL-FS-1148
Yuki Tanaka
HW-007
MediumTraining gapNew hire ran the deburr station without a sign-off on the AMS 2304 acceptance criteria.In review
Apr 27, 11:55 AMHAL-LG-2207
Tomás Ferreira
HW-004
HighTraining gapOperator not yet certified on the 5-axis probing macro this op requires.Open
Apr 27, 06:20 AMHAL-LG-2218
Naomi Park
HW-011
HighTolerance ambiguityTwo callouts on the same surface conflict by 0.0002, no engineering note resolves it.Open
Apr 27, 02:57 AMHAL-ST-3091
Devon Walker
HW-006
MediumFixture undocumentedBay 4 tombstone fixture has an undocumented spacer stack required for this part.In review
Apr 27, 12:22 AMHAL-LG-2207
Linnea Holm
HW-005
MediumFixture undocumentedBay 4 tombstone fixture has an undocumented spacer stack required for this part.Training scheduled
Apr 26, 10:47 PMHAL-ST-3104
Naomi Park
HW-011
LowSOP gapSOP step 7 references a tool number that is not in the current crib loadout.In review
Apr 26, 07:47 PMHAL-ST-3091
Devon Walker
HW-006
MediumSOP gapNo SOP step covers the deburr pass between op 30 and op 40.Open
Apr 25, 02:04 PMHAL-EN-4412
Erik Lindqvist
HW-010
MediumTraining gapOperator not yet certified on the 5-axis probing macro this op requires.Training scheduled
Apr 25, 01:21 AMHAL-LG-2218
Ana Reyes
HW-001
MediumTolerance ambiguityPrint calls out 0.0005 TIR but does not specify the reference datum.Training scheduled
Apr 25, 01:11 AMHAL-ST-3104
Devon Walker
HW-006
HighSupplier issueSupplier shipped a heat treat that is one revision behind the current spec.In review
Apr 24, 03:57 PMHAL-FS-1148
Brett Kowalski
HW-012
HighTraining gapNew hire ran the deburr station without a sign-off on the AMS 2304 acceptance criteria.Open
Apr 24, 01:21 PMHAL-EN-4412
Linnea Holm
HW-005
MediumSupplier issue3.1 cert references a test method the supplier has not been requalified on.Training scheduled
Apr 22, 11:22 PMHAL-LG-2218
Carla Mendez
HW-009
HighSupplier issueIncoming material cert lot does not match the heat number on the bar stock.Open
LMS pipeline
Gaps feeding training modules
Incoming Supplier Cert Verification
9
How to read a 3.1 cert, what to escalate, and the ERP flag chain when material lots arrive non-conforming.
72
5-Axis Mill Setup, Advanced
6
Probing, work-offset chains, and tombstone fixturing for the Mazak Variaxis cells in Bay 1 and Bay 4.
24
Surface Finish and FPI Prep
6
Surface finish acceptance per AMS 2304 and fluorescent penetrant prep for landing gear components.
51
Tolerance Inspection on M-7 Fixtures
5
Refresh on profile, position, and runout callouts when fixturing on the M-7 family. Current revision dated last quarter, supersedes the 2024 work instruction.
23
Active SOP Revision Awareness
4
How to confirm you are working from the current SOP revision, not a printout that was already superseded.
13
Fastener Torque Standards Refresh
2
Aerospace fastener torque ranges and witness mark protocol. Covers titanium, A286, and Hi-Lok callouts.
2
Soft-Jaw Fixturing for Thin-Wall Parts
2
Soft-jaw and vacuum-fixture practice for the thin-wall fuel manifold and bulkhead families.
11